CAN/CSA-ISO 8637-2:21 PDF

CAN/CSA-ISO 8637-2:21 PDF

Name:
CAN/CSA-ISO 8637-2:21 PDF

Published Date:
08/01/2021

Status:
Active

Description:

Extracorporeal systems for blood purification - Part 2: Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters (ISO 8637-2:2018, IDT)

Publisher:
Canada National Standard/Canadian Standards - ISO

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$29.1
Need Help?

CSA Preface 

This is the first edition of CSA ISO 8637-2, Extracorporeal systems for blood purification - Part 2: Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters , which is an adoption without modification of the identically titled ISO (International Standards Organization) Standard 8637-2 (first edition, 2018-07). It replaces CAN/CSA-ISO 8638:12 (adopted ISO 8638:2010), Cardiovascular implants and extracorporeal systems - Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters. 

CSA Group acknowledges that the adoption of this Standard was made possible, in part, by the financial support of the governments of Alberta, British Columbia, Manitoba, New Brunswick, Newfoundland and Labrador, Northwest Territories, Nova Scotia, Nunavut, Ontario, Prince Edward Island, Québec, Saskatchewan, and Yukon, as administered by the Canadian Agency for Drugs and Technologies in Health (CADTH). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope 

WARNING - Other requirements and other EU Directives may be applicable to the product(s) falling within the scope of this document. This document specifies requirements for the blood circuit for devices used in extracorporeal blood filtration therapies such as, but not limited to, haemodialysis, haemodiafiltration, haemofiltration and transducer protectors (integral and non-integral) intended for use in such circuits. This document does not apply to: 

- haemodialysers, haemodiafilters or haemofilters; 

- plasmafilters; 

- haemoperfusion devices; 

- vascular access devices; 

- blood pumps; 

- pressure monitors for the extracorporeal blood circuit; 

- air detection devices; 

- systems to prepare, maintain or monitor dialysis fluid; 

- systems or equipment intended to perform haemodialysis, haemodiafiltration, haemofiltration or haemoconcentration. 

NOTE 1 Requirements for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators are specified in ISO 8637-1, and requirements for plasmafilters are specified in ISO 8637-3. 

NOTE 2 Extracorporeal blood tubing sets can also be used for other extracorporeal therapies such as haemoperfusion, plasmafiltration and plasma adsorption.


File Size : 1 file , 1.5 MB
ISBN(s) : 9781488339653
Number of Pages : 31
Product Code(s) : 2429674, 2429673, 2429673, 2429674
Published : 08/01/2021

History


Related products


Best-Selling Products

JEDEC EIA 318-B
Published Date: 07/01/1996
MEASUREMENT OF REVERSE RECOVERY TIME FOR SEMICONDUCTOR SIGNAL DIODES
$17.7
JEDEC EIA 323 (R2002)
Published Date: 03/01/1966
AIR-CONVECTION-COOLED, LIFE TEST ENVIRONMENT FOR LEAD-MOUNTED SEMICONDUCTOR DEVICES
$15.3
JEDEC EIA 365 (R1984)
Published Date: 11/01/1969
PERFORMANCE TEST PROCEDURE FOR SOLAR CELLS AND CALIBRATION PROCEDURE FOR SOLAR CELL STANDARDS FOR SPACE VEHICLE SERVICE
$17.7
JEDEC EIA 397-1
Published Date: 07/01/1980
ADDENDUM No. 1 TO EIA-397
$31.8
JEDEC EIA 397
Published Date: 06/01/1972
RECOMMENDED STANDARD FOR THYRISTORS
$68.4
JEDEC EIA 557B
Published Date: 02/01/2006
STATISTICAL PROCESS CONTROL SYSTEMS
$22.2